89
Analog output (4) characteristics selection ([optional board] (AOT4))
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
G-13
Analog output (4) characteristics
selection
0: Output voltage
1: Output current
2: Armature current command
3: Speed
4: Speed command
5: Internal PLC function
6: Calibration
7: Internal monitor
8: [For special adjustment]
- 1
-
Analog output (4) characteristics selection (G-13):
In this parameter, select the type of output characteristics of [option board] (AOT4). * For more information,
refer to the Optional Instruction Manual.
Analog output (5) characteristics selection ([optional board] (AOT5))
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
G-14
Analog output (5) characteristics
selection
0: Output
voltage
1: Output
current
2: Armature current command
3: Speed
4: Speed
command
5: Internal PLC function
6: Calibration
7: Internal
monitor
8: [For special adjustment]
9: Output voltage (4 to 20 mA)
10: Output current (4 to 20 mA)
11: Armature current command (4 to 20 mA)
12: Speed (4 to 20 mA)
13: Speed command (4 to 20 mA)
14: Internal PLC function (4 to 20 mA)
15: Calibration (4 to 20 mA)
- 1
-
Analog output (5) characteristics selection (G-14):
In this parameter, select the type of output characteristics of [option board] (AOT5). * For more information,
refer to the Optional Instruction Manual.
Line speed setting
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
G-15
Line speed monitor adjustment
0.0 to 2000.0
0.1
0.0
-
Line speed monitor adjustment (G-15):
Adjust the amount of gain of the monitor item (Line speed
) displayed on the console (SET66-Z).
Set the line speed at the time when a value of the Maximum speed (A-00) is reached.
A value displayed in the line speed monitor is calculated in the following formula:
Monitor speed x Line speed monitor adjustment (G-15)/Maximum speed (A-00)