31
6.3. Area b (Operation Sequence Setting Area)
Symbols of Driving ReWrite
: ReWrite is possible, ×: ReWrite is not possible
Console
panel
monitor
display
Contents
Setting range (selecting item)
Factory-
initialized
data
Unit
Driving
ReWrite
b-00
Setting data rewrite protection
oFF (None)
on (Setting data rewrite protection)
oFF -
×
b-01
Stop mode selection
0: Free stop
1: Deceleration stop
1 -
b-02
Stop speed
0 to 300
30 r/min
b-03 [No
function]
-
-
-
-
b-04 [No
function]
-
-
-
-
b-05
JOG stop mode selection
0: Free stop
1: Deceleration stop
0 -
b-06
JOG stop speed
0 to 300
30 r/min
b-07
Instantaneous power interruption
restart
oFF (Not restart)
on (Restart)
oFF -
×
b-08
Reverse rotation/reverse voltage
prohibition mode selection
0: Normal
1: Prohibit operation in the direction opposite
to command
2: Prohibit opposite direction
0 -
×
b-09
Command input when coupled
0: Terminal block
1: Console panel [SET66-Z]
2: Communication option
1 -
×
b-10
Speed/armature voltage command
input selection
0: Interlock
1: Analog input (1) [VFC66-Z TB1] (AIN1)
2: Console panel [SET66-Z]
3: Communication option
4: Analog input (2) [optional board] (AIN2)
5: [For expanded options]
*1
6: Analog input (3) [optional board] (AIN3)
7: Internal PLC function
0 -
×
b-11
Operation command input selection
0: Interlock
1: Terminal block [VFC66-Z TB1] (ST-F)
2: Console panel [SET66-Z]
3: Communication option
0 -
×
b-12
JOG command input selection
0: Interlock
1: Terminal block
[VFC66-Z TB1] (MI1 to MI5)
*2
[Optional board] (MI6 to MI17)
*2
2: Console panel [SET66-Z]
3: Communication option
0 -
×
b-13
Forward powering armature current
limit
0 to value that depends on rated motor
armature current <A-04>
*3
* The rated current of VF66B (DC motor drive)
is 100%
150 %
b-14
Forward regenerative armature current
limit
-value that depends on rated motor armature
current <A-04>
*3
to 0
* The rated current of VF66B (DC motor drive)
is 100%
-150 %
b-15
Reverse powering armature current
limit
-value that depends on rated motor armature
current <A-04>
*3
to 0
* The rated current of VF66B (DC motor drive)
is 100%
-150 %