How Voice Processing Operates
Feature Programming
Strata CIX40 Voice Processing Programming Manual 7/06
3-17
Ho
w V
o
ice
Proc
essin
g
Ope
rates
Messages—New, Pending and Saved
Mailbox Feature
Set
Saved Msg Que
field (Users Menu Options Screen) to Yes to create two queues, new and
saved, or No for one queue for all messages.
Pending Messages
Any message listened to for a shorter amount of time than that specified in the
msg_pending_threshold
parameter is kept as a new message. The message remains in the
New Message Queue and the Message Waiting Off notification type is not processed. A
message that is listened to longer than the time specified but is not listened to all the way
through or manually saved (by pressing
2
) or deleted (by pressing
3
) is considered a Pending
Message. The message remains in the New Message Queue and the Message Waiting Off
notification type
is
processed.
This feature defaults to disabled. To enable it set the
Message Pending
(Users Menu Options
screen) field to On. To reset the threshold time, use the
msg_pending_threshold
(default 5
seconds) parameter (values are 3~10 seconds).
Messages—Urgent
Mailbox Feature
Set the
Type
field (Notify Menu) to URGENT to notify the user of urgent messages.
Multiple System Languages
System-wide Feature
System Prompts: English or Spanish
System Greetings:
•
English only
•
prompt plays in English, repeats in Spanish
•
Spanish only
•
prompt plays in Spanish, repeats in English
Note
These options are set using jumpers SW2 and SW3 on the GVPH card and the
prompt_file
parameter in the Stratagy Admin UADM2 software. See Chapter 1 in
the
Strata CIX40 I&M Manual
for instructions.
Name (and Extension) Control
Mailbox Feature
This feature defaults to enabled (Yes). To disable this feature, set the
Record Name?
field
(Users Menu Options screen) to No.
The amount of recording time defaults to 5 seconds. To change the amount of recording time
reset the
nam_maxlen
parameter to 1~99 seconds.
Paging – Office
Mailbox Feature
This feature is set using the
Type
field (Notify Menu) to RELAY.