SELF-DIAGNOSTIC MODE
3 - 21
3.10.3
Functions
[A] 1. Revert factory initial status HDD
Select this to dispose of the ADI-HDD as well as the equipment.
When this item is selected, all data in the HDD are deleted and the HDD is reverted to its initial status at
the factory shipment.
This operation requires only a few seconds; however, you must create the partition in the HDD in the
3C mode (Format HDD) and reinstall the HDD data in the 49 mode to make the HDD reusable.
When "1" is selected and then [START] button is pressed, the menu below appears.
To start, press the [START] button.
Fig. 3-10
When the operation is finished, the result appears on the menu.
Fig. 3-11
Notes:
If the equipment is started in the normal mode with this condition, an HDD mounting error occurs.
HDD Assist Mode
Current HDD type: ADI HDD
Select number (1-2) and press START key
1. Revert factory initial status HDD
2. Remove key
System Firmware Version
Update Mode
: xxxx(x.x.x.x)
: 4c Mode
=>
Confirmation Screen
Are you sure ???
Press START to continue
Press STOP to cancel
HDD Assist Mode
Current HDD type: ADI HDD
Select number (1-2) and press START key
1. Revert factory initial status HDD
2. Remove key
System Firmware Version
Update Mode
: xxxx(x.x.x.x)
: 4c Mode
=>
Data in the HDD has been complately erased.
Press SoftPower Key to Switch Off