REPLACEMENT OF PC BOARDS/HDD
6 - 26
[I]
Backup license
Notes:
If "3. License SRAM to FROM" is performed by mistake, carry out the following procedure.
P. 6-30 "[ 1 ] Re-registration when the board is replaced"
(1) Turn the power ON while pressing [3] and the [CLEAR] button simultaneously.
(2) Enter the password, and then press the [OK] button. (If the password is not set for Service, press
the [ENTER] button without entering anything.)
(3) Key in [5] to select "5. Key Backup Restore", and then press the [START] button.
(4) Key in [4] to select "4. License FROM to SRAM", and then press the [START] button.
(5) Wait until the backup of the license is completed. "Operation Complete" is displayed.
(6) Restart the equipment after the backup is completed.
(7) Turn the power OFF.
[J] Initialize SRAM board
(1) Start up with the Setting Mode (08).
(2) Initialize the SRAM error.
1.When “SRAM REQUIRES INITIALIZATION” is displayed on the LCD, check the destination
and then press the [START] button.
If the destination is not correct, key in the correct one and then press the [START] button.
2.After the confirmation message is displayed, press the [INTERRUPT] button.
(3) Perform the panel calibration (08-9050).
1.Touch the center of “+” mark displayed on the upper left of the LCD.
2.Touch the center of “+” mark displayed on the upper right of the LCD.
3.Touch the center of “+” mark displayed on the lower left of the LCD.
4.Touch the center of “+” mark displayed on the lower right of the LCD.
(4) Set the line mode to OFF by setting the value of 08-9010 to "0".
(5) Perform the initialization at the software version upgrade (08-9030).
(6) Initialize the NIC information (08-9083).
(7) Enter the serial number (08-9601).
Key in the serial number on the label attached to the rear cover of the equipment, and then press
the [OK] button.
(8) Turn the power off.
[K] Reinstall license
If the license was returned in "[B]Return License", reinstall it with the following procedure.
(1) Turn the power ON while pressing [0] and [8] simultaneously.
(2) Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [ENTER] button without entering anything.)
(3) Key in [3840], and then press the [START] button.