e-STUDIO477S/527S/477SL
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSTIC MODE
3 - 2
Notes:
The following modes cannot be carried out since they are provided only for production.
[2]+[CLEAR]+[POWER]
[7]+[CLEAR]+[POWER]
[8]+[CLEAR]+[POWER]
The menu below can be carried out in the following mode; however, there is no effect on the
equipment even if it is done.
[9]+[CLEAR]+[POWER]
0. Turn Line Mode ON
1. Turn Line Mode OFF
3. Restore Machine Information
[D] State transition diagram of self-diagnosis modes
Fig. 3-1
*1 If you have used a self-diagnostic mode, turn the power OFF before the customer starts using the
equipment
*2 Mode shown in the table "[C] List of modes"
[E] About each mode
• Control panel check mode (01)
Operation procedure
Notes:
• A mode can be cancelled by [POWER] OFF/ON when the LED is lit and the LCD is blinking.
• Button Check
Buttons with LED: Press to turn OFF the LED.
Buttons without LED: Press to display the message on the control panel.
Button on touch panel: Press to display the initial screen displayed at power-ON. Press
[execution] on the touch panel and then the [CLEAR] button on the control panel. The screen
then returns to the Button Check menu.
Authentication
screen
Normal
Warming up
Ready
[POWER]
OFF
To user
Each mode
Self-diagnosis
mode
*1
*2
[POWER]
ON
[0][1]
[POWER]
LED lit/
LCD blinking
[START]
[START]
(Button check)
[POWER] OFF/ON
(Exit)