e-STUDIO477S/527S/477SL
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
REPLACEMENT OF PC BOARDS/HDD
6 - 10
6.2.2
HDD fault diagnosis
This code displays the HDD operation history, which is recorded in the HDD, on the control panel. HDD
failure can be diagnosed or predicted with the information displayed.
1. Display
The following screen is displayed with setting code 08-9065. You can also refer to the same
information by pressing the [ON/OFF] button while pressing [5] and [C] simultaneously and then
selecting "5. SMART Info".
Fig. 9-1
- Items supported differ depending on the HDD manufacturer.
- “---” is displayed on the VALUE, NAV and Worst columns if items are not supported.
2. Usage
The combination of the values of ID=05 and c5 is used to diagnose whether or not the HDD has a
physical failure when HDD failure is suspected (service call F100 - F109 or F120 or F124 occurred).
Result
Description
Diagnosis
ID
VALUE
05
0
Low possibility of physical failure
HDD
replacement is
not required.
c5
0
05
From 1 to 999
Defective sector has been reassigned and HDD
is recovered.
HDD
replacement is
not required.
c5
0
05
Any value
High possibility of defective sector existence.
(There will be a possibility of physical failure
depending on the use of HDD.)
HDD
replacement is
recommended.
c5
1 or more
05
Either one is at least
1000.
High possibility of physical failure
HDD
replacement is
recommended.
c5
HDD manufacturer
Model name
HDD serial number
Summary of Contents for e-Studio477s