e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
Debug level setting
Sets the output volume of debug log. When the
value is set to "0", the performance may decrease.
0: Debug log level – high
2: Debug log level - normal
Setting
mode
System
8942
2
0, 2
1
-
08
Automatic user registration
for card authentication
0: Disabled
1: Enabled
Setting
mode
System
User interface
Card reading
device
8947
0
0~1
1
SSDK
08
Language package
information
Displays the information of the installed language
package.
Setting
mode
System
User interface
8948
2
Yes
-
08
External version of HD data
External version of file system for system software
Setting
mode
System
Version
8952
2
-
08
Panel Help
Displays the language package information of the
installed Panel Help.
Setting
mode
System
User interface
General
Language
package
information
8968
2
Yes
-
08
WebHelp
Displays the language package information of the
installed WebHelp.
Setting
mode
System
User interface
General
Language
package
information
8969
2
Yes
-
08
Service UI
Displays the language package information of the
installed Service UI.
Setting
mode
System
User interface
General
Language
package
information
8970
2
Yes
-
08
Installation of language
package
Installs the language package.
Setting
mode
System
User interface
General
8971
3
Yes
-
08
Length of public key
0: 1024 bit
1: 2048 bit
Setting
mode
System
General
Self-certificate
8973
1
0~1
1
SYS
08
Signature algorithm
0: SHA1
1: SHA224
2: SHA256
3: SHA384
4: SHA512
Setting
mode
System
General
Self-certificate
8974
0
0~4
1
SYS
08
Data clearing of Point and
Point and Print in the equipment is deleted when
this code is performed. Perform this code when a
trouble occurs such as when uploading Point and
Print is not possible. After performing this code,
upload Point and Print from [Maintenance] menu in
the [Administration] menu of TopAccess.
Setting
mode
System
Network
8975
3
SYS
08
Copy
Sets whether the originals that are prohibited from
duplication are detected or not.
0: Detection disabled
1: Detection enabled
Setting
mode
System
General
Detection of
originals
prohibited from
duplication
8977
0
1
0~1
4
SYS
08
Scan
Sets whether the originals that are prohibited from
duplication are detected or not.
0: Detection disabled
1: Detection enabled
Setting
mode
System
General
Detection of
originals
prohibited from
duplication
8977
1
1
0~1
4
SYS
08
FAX
Sets whether the originals that are prohibited from
duplication are detected or not.
0: Detection disabled
1: Detection enabled
Setting
mode
System
General
Detection of
originals
prohibited from
duplication
8977
2
1
0~1
4
SYS
08
Execution of Remote Scan
while control panel is
operated
Sets whether the remote scanning is enabled or
disabled if the user is logged in using the control
panel when user authentication or department
management is enabled.
0: Disabled
1: Enabled
Setting
mode
System
Scanning
8980
0
0~1
12
NIC
48
Ver03
08 Setting Mode