2) Sensors and switches
3) Electromagnetic clutch
4) Solenoids
Symbol
Name
Function
Remarks
P-I
S1
HOME-SNR
CIS home position sensor
Detecting CIS home position
Fig. 2-3
10-106
S2
PLTN-SNR
Platen sensor
Detecting the opening/closing of platen
cover or RADF
Fig. 2-3
9-101
S3
TEMP/HUMI-SNR
Temperature/humidity sensor
Detecting the temperature and humidity
inside the equipment
Fig. 2-4
5-16
S4
RGST-SNR
Registration sensor
Detecting the transporting paper at the
registration roller section
Fig. 2-7
15-107
S5
EXIT-SNR
Exit sensor
Detecting the transporting paper at the
exit section
Fig. 2-5
24-8
S6
ATTNR-SNR
Auto-toner sensor
Detecting the density of toner in the
developer unit
Fig. 2-6
21-46
S7
EMP-SNR
Paper empty sensor
Detecting presence/absence of paper
in the drawer
Fig. 2-8
15-107
S8
SFB-SNR
Bypass paper sensor
Detecting presence/absence of paper
on the bypass tray
Fig. 2-9
13-101
S9-13
APS 1-3, APS-C, APS-R
Automatic original detection sensor
Detecting original size
*
S9: only for A4 series models
Fig. 2-3
9-9,
9-19
SW1
MAIN-SW
Main switch
Turning ON/OFF of the equipment
Fig. 2-4
5-4
SW2
ADU-COV-INTLCK-SW
ADU cover opening/closing interlock
switch
Controlling cutoff and supply of the 24V
voltage by opening/closing of the ADU
cover
Fig. 2-4
6-8
SW3
FRNT-COV-INTLCK-SW
Front cover opening/closing interlock
switch
Controlling cutoff and supply of the 24V
voltage by opening/closing of the front
cover
Fig. 2-4
1-5
SW4
FRNT-COV-SW
Front cover opening/closing switch
Detecting the opening/closing of the
front cover
Fig. 2-4
1-101
SW5
CST-SW
Drawer detection switch
Detecting presence/absence of the
drawer
Fig. 2-8
16-110
Symbol
Name
Function
Remarks
P-I
CLT1
RGST-CLT
Registration clutch
Driving the registration roller
Fig. 2-7
16-21
Symbol
Name
Function
Remarks
P-I
SOL1
CST-SOL
Pickup solenoid
Controlling the power transmission of
the feed roller
Fig. 2-7
16-9
SOL2
SFB-SOL
Bypass pickup solenoid
Controlling the power transmission of
the bypass pickup roller
Fig. 2-9