10
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO167/207/237
PAPER FEEDING SYSTEM
10 - 19
[J]
Damp heater unit (DH3) / Dummy plate
Notes:
•
This damp heater unit is optional for NAD, CND and MJD.
•
The dummy plate is attached to the equipment in which the damp heater unit is not installed.
To take it off, perform the procedure from step (3).
(1)
Take off the rear cover.
"
P.2-22 "[J] Rear cover"
(2)
Release the harness from the harness clamp
and disconnect the connector.
Fig. 10-31
(3)
Take off the process unit.
"
P.11-9 "[A] Process unit"
(4)
Remove 1 screw and take off the damp
heater unit or dummy plate while sliding it to
the rear side and lifting it up.
Fig. 10-32
Connector
Damp heater unit or
dummy plate
Screw