Electrical
System
Reelmaster 5500-D
Page 5 - 35
Electrical System (Rev. C)
Service and Repairs
NOTE: For more component repair information, see
the Kubota Workshop Manual, Diesel Engine, 05 Series
at the end of Chapter 3 - Kubota Diesel Engines.
Battery Storage
If the machine will be stored for more than 30 days
1. Remove the battery and charge it fully (see Battery
Service).
2. Either store battery on a shelf or on the machine.
3. Leave cables disconnected if the battery is stored on
the machine.
4. Store battery in a cool atmosphere to avoid quick de-
terioration of the battery charge.
5. To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service).
Battery Care
1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will run down more rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced
while charging can dissipate. Since the gases
are explosive, keep open flames and electrical
sparks away from the battery; do not smoke.
Nausea may result if the gases are inhaled. Un-
plug charger from electrical outlet before con-
necting or disconnecting charger leads to or
from battery posts.
IMPORTANT: Do not remove fill caps while clean-
ing.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
case clean because a dirty battery will discharge slowly.
A. Clean battery by washing entire case with a solu-
tion of baking soda and water. Rinse with clear water.
B. Coat battery posts and cable connectors with
Grafo 112X (skin-over) grease (Toro Part No.
505-47) or petroleum jelly to prevent corrosion.
3. Battery cables must be tight on terminals to provide
good electrical contact.
WARNING
Connecting cables to the wrong post could re-
sult in personal injury and/or damage to the
electrical system.
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (-) cable first. Scrape
clamps and terminals separately. Reconnect cables
with positive (+) cable first. Coat battery posts and cable
connectors with Grafo 112X (skin-over) grease (Toro
Part No. 505-47) or petroleum jelly to prevent corrosion.
5. Check electrolyte level every 25 operating hours,
and every 30 days if machine is in storage.
6. Maintain cell level with distilled or demineralized wa-
ter. Do not fill cells above the fill line.
Summary of Contents for 00075SL
Page 2: ...Reelmaster 5500 D ...
Page 4: ...Reelmaster 5500 D ...
Page 6: ...Reelmaster 5500 D ...
Page 64: ...Reelmaster 5500 D Hydraulic System Rev C Page 4 26 This page is intentionally blank ...
Page 170: ...Reelmaster 5500 D Page 5 40 Electrical System Rev C ...
Page 192: ...Reelmaster 5500 D Differential Axle Page 6 22 ...
Page 254: ...Reelmaster 5500 D Groomer Rev C Page 8 1 14 ...
Page 278: ...Reelmaster 5500 D Page 10 2 Electrical Diagrams Rev C ...
Page 284: ...Rev C Page 10 8 Harness Drawing Reelmaster 5500 D Serial Number 210000401 to 210999999 ...
Page 285: ...Rev C Page 10 9 Harness Diagram Reelmaster 5500 D Serial Number 210000401 to 210999999 ...
Page 286: ...Rev C Page 10 10 Harness Drawing Reelmaster 5500 D Serial Number 220000001 to 220999999 ...
Page 287: ...Rev C Page 10 11 Harness Diagram Reelmaster 5500 D Serial Number 220000001 to 220999999 ...
Page 288: ...Rev C Page 10 12 Harness Drawing Reelmaster 5500 D Serial Number Above 230000000 ...
Page 289: ...Rev C Page 10 13 Harness Diagram Reelmaster 5500 D Serial Number Above 230000000 ...
Page 290: ...Reelmaster 5500 D ...