2-19
(2) Fasten PTFE sealing antenna with O-ring. Pass through flange and washer, then secured with
locking nut. Let transmitter fix to PTFE sealing antenna unit by locking nut.
NOTE:
・
Please apply the grease lubricating for O-ring.
・
Please be careful there is no adhesion of dirt for O-ring through assembling.
Locking nut
Transmitter
Washer
Flange
(Option)
PTFE sealing antenna
O-ring
Locking nut of
transmitter head
Fig. 2.10.2.2 Antenna assembling