10-9
10.3 Antenna specifications
Table 10.3.1 Cone antenna
Antenna type
Cone
Diameter
・
2": (half-power beam width: 18°)
・
4": (half-power beam width: 8°)
Material SUS316L,
PTFE
Operating
conditions
Process
temperature
Non-Ex
FKM:-10 to +150 °C
Kalrez:-20 to +150 °C
VMQ:-40 to +150 °C
NOTE:
For Ex equipment, please refer to the “Safety Instructions”.
Process
pressure
-0.1 to 1.5 MPa
Process
fitting
Flange
1)
(JIS B2220, DIN 1092-1, ANSI B16.5 etc)
1) Option
Table 10.3.2 PTFE sealing antenna
Antenna type
PTFE
sealing
Diameter
・
2": (half-power beam width: 18°)
・
4": (half-power beam width: 8° )
Material SUS304,
PTFE
Operating
conditions
Process
temperature
Non-Ex
FKM:-10 to +200 °C
VMQ:-40 to +180 °C
NOTE:
For Ex equipment, please refer to the “Safety Instructions”.
Process
pressure
-0.1 to 1.5 MPa
Process
fitting
Flange
1)
(JIS B2220, DIN 1092-1, ANSI B16.5 etc)
1) Option
Table 10.3.3 Rod antenna
Antenna type
Rod
Diameter
・
1": (half-power beam width: 25°)
Material
SUS304, PTFE(or PFA)
Operating
conditions
Process
temperature
Non-Ex
VMQ:-40 to +150 °C
NOTE:
For Ex equipment, please refer to the “Safety Instructions”.
Process
pressure
-0.1 to 1.5 MPa
Process
fitting
Flange
1)
(JIS B2220, DIN 1092-1, ANSI B16.5 etc)
1) Option
Summary of Contents for KRG-10
Page 1: ...Document No KF13 001K Microwave Level Gauge RG 10 User s Guide...
Page 9: ...8 Blank...
Page 13: ...12 Blank...
Page 51: ...3 8 Blank...
Page 55: ...4 4 Blank...
Page 171: ...9 2 Blank...
Page 190: ...10 19 M20 1 5 Fig 10 7 6 Cable gland Only Non Ex type...
Page 193: ...11 2 Blank...
Page 197: ...12 4 Blank...
Page 199: ...Blank...