6-78
(8) Setting HART variables (*It is supported by firmware version 1.6.1 or later)
To set HART variables, switch the operation mode in the measurement operation area to
"HART Variables". Click [Setting Items] --> "Read" button to read the assignment of HART
variables from the device. Then, click [Setting Items] --> "Write" button to write the assignment
of HART variables to the device.
Fig. 6.9.19 Setting HART variables
HART variables
- Primary Variable (PV): Setting item to be assigned to PV
(Level / Distance / Volume / Flow / Signal Amp.)
- Secondary Variable (SV): Setting item to be assigned to SV
(Level / Distance / Volume / Flow / Signal Amp. / Unused / Electronic
Temp. / Maximum Volume / Maximum Flow / Volume Ratio / Flow
Ratio / Elapsed Time from Start / Search Count / Elapsed Time from
Final Search / Margin of Sensitivity)
- Tertiary Variable (TV): Setting item to be assigned to TV
(Level / Distance / Volume / Flow / Signal Amp. / Unused / Electronic
Temp. / Maximum Volume / Maximum Flow / Volume Ratio / Flow
Ratio / Elapsed Time from Start / Search Count / Elapsed Time from
Final Search / Margin of Sensitivity)
- Quaternary Variable (QV): Setting item to be assigned to QV
(Level / Distance / Volume / Flow / Signal Amp. / Unused / Electronic
Temp. / Maximum Volume / Maximum Flow / Volume Ratio / Flow
Ratio / Elapsed Time from Start / Search Count / Elapsed Time from
Final Search / Margin of Sensitivity)
HART variables setting "Read" button
HART variables setting "Write" button
Summary of Contents for KRG-10
Page 1: ...Document No KF13 001K Microwave Level Gauge RG 10 User s Guide...
Page 9: ...8 Blank...
Page 13: ...12 Blank...
Page 51: ...3 8 Blank...
Page 55: ...4 4 Blank...
Page 171: ...9 2 Blank...
Page 190: ...10 19 M20 1 5 Fig 10 7 6 Cable gland Only Non Ex type...
Page 193: ...11 2 Blank...
Page 197: ...12 4 Blank...
Page 199: ...Blank...