23
© Tieline Pty. Ltd. 2015
Bridge-IT XTRA Manual
Features
Description
1
-16dBu
PPM meter low point
2
+4dBu
Nominal 0vu reference level at +4dBu
3
+20dBu
+20dBu indication that should not be exceeded to prevent clipping
at +22dBu
4
PPM meter in clip
PPM indication displays a solid section at the right-hand end
when audio is in danger of clipping
Audio Metering when Connecting to Tieline G3 Codecs
New generation Genie, Merlin and Bridge-IT IP codecs have more audio headroom than Tieline G3
audio codecs, therefore metering needs to be adjusted when connecting to a Commander or i-Mix
G3 codec. The G3 metering scale is between -11dBu and +18dBu and audio levels should average
around the nominal 0vu point. Audio peaks should not exceed +16dbu as indicated on the PPM
meter.
Features
Description
1
-11dBu
PPM meter low point
2
+4dBu
Nominal 0vu reference level at +4dBu
3
+16dBu
+16 indication where audio will clip/distort
Channel 1 Mic/Line Level Audio Adjustment
The default input level setting in the codec for channel 1 is line level. To adjust this setting for a mic-
level or unbalanced source:
1. Press the
SETTINGS
button.
2. Navigate to
Audio
and press
.
Summary of Contents for Bridge-IT XTRA