2-3-2. Von Voltage Settings
2-3-2-1. Von Voltage Level
Description
The Von Voltage is the threshold voltage at
which the load module will start to sink current.
Time
Von voltage
Von
V
Time
I
V out
Load
on
Operation
1.
Press
Main
>
Configure[F5]
>
Other[F2]
and
set the
Von Voltage
level.
Range:
Von Voltage: 0.00~rating voltage
2-3-2-2. Von Voltage Latch
Description
When Von Latch is set to ON, the load will
continue to sink current after being “latched”,
even if the voltage drops below the Von Voltage
threshold level.
When Von Latch is set to OFF, the load will turn
off when the voltage drops below the Von
Voltage threshold level.
By default Von Latch is set to OFF.
Time
Von Latch = OFF
Von
V
Time
I
V out
Load
on
Load
off
Load
on