131
A COM
17 Connected to the negative load input terminal.
N.C.
18
A COM
19 Connected to the negative load input terminal.
+15V
ALARM INPUT
20 Controls the on/off of the load booster power
(cannot be used for multiple purposes).
J1 Connector Booster
Pin name
Pin number
Description
N.C.
1
N.C.
2
A COM
3 Connected to the negative load input terminal.
SUM I MON
4 Connected to SUM I MON of the J2 connector.
PRL IN+
5 Connected to PRL OUT+ of the J2 connector.
PRL IN-
6 Connected to PRL OUT- of the J2 connector.
LOAD ON/OFF
CONT
7 "Turns on the load with low (or high) TTL level signal.
Pulled up the internal circuit to 5 V using
10 kΩ."
N.C.
8
RANGE CONT 0
9 "External range switch input*1 *2
Pulled up the internal circuit to 5 V using 10 kΩ."
ALARM INPUT
10 Activates an alarm with high (or low) TTL level signal
input. Pulled up by the internal circuit to 5 V.
N.C.
11
A COM
12 Connected to the negative load input terminal on the
rear panel.
N.C.
13
N.C.
14
N.C.
15
ALARM STATUS
16 Turns on when an alarm (OVP, OCP, OPP, OTP, RVP,
or UVP) is activated or when an external alarm is
applied. Open collector output by a photocoupler.*3
STATUS COM
17 STATUS signal common for pins 16.
N.C.
18
A COM
19 Connected to the negative load input terminal on the
rear panel.
+15V
20 Controls the on/off of the load booster power (cannot
be used for multiple purposes).
*1 Valid only when the front panel settings are
H range.
*2
RANGE CONT 0
H range
1
M range
1
*3 The maximum applied voltage of the photocoupler is
30 V; the maximum current is 8 mA.