103
4. EXTERNAL CONTROL
4-1. Analog Control
The Analog Control subsection describes how to use the J1 Frame
Control Connector for voltage or resistance control. The J2 connector,
located under the J1 connector is used for parallel control. See page
129 for the details J1 and J2 connectors.
4-1-1. J1 Connector Overview
Description
The J1 External Control Connector is a standard
Mil 20 pin connector (OMRON XG4A IDC plug).
The connector is used for all analog control. The
pins are used to determine what mode is used.
See the appendix on page 129 to view the
contact pin assignment of the J1 connector.
WARNING
Some pins on the frame control connector have
the same potential as the front and rear
terminals.
To prevent electric shock, ensure that the cover
for both the J1 and J2 External Control
connectors are used when the connectors are
not in use.
Pin Assignment
FRAME CONT
J 1
1
2
19
20
J1 Connector Pin assign
No
Name
No
Name
1
Ext-V In / Ext-R In (+)
2
I MON Out
3
Ext-V In / Ext-R In (-)
4
SUM I Mon Out
5
PRL In(+)
6
PRL In(-)
7
Ext-Load On(+)
8
I Rang)
9
I Rang)
10
Ext Alarm In(+)
11
Ext Trigger In(+)
12
A COM
13
Load On Out(+)
14
I Range S)
15
I Range S)
16
Alarm Out(+)
17
STATUS COM
18
NC
19
Short Signal Our(+)
20
Short Signal Our(-)
Summary of Contents for LSG SERIES
Page 8: ......
Page 23: ...11 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6 ...
Page 149: ...137 7 6 Operating Area LSG 175 ...
Page 150: ...138 LSG 350 ...
Page 151: ...139 LSG 1050 ...
Page 166: ......