90
Start OCP Test
5.
Press
OCP
[F1] to turn the OCP function on if it
is off.
6.
The OCP function can be started by turning the
load on by pressing
Shift
+
Load
On/
Off
.
The test current will increase from the
Start C value to the End C value in steps
according to the Step C value, until the
test has finished.
The test will start running when the power
supply voltage is greater than the Trig V
voltage.
Example:OCP
Function running
OCP
RS232
31/Oct/2013
OCP Test
0.998
V
153.10
mA
0.1528
w
Set Curr:
Fetch Volt:
2.000
1.500
1.000
0.91
0.92
0.91
Measured voltage for
last three steps
Measured voltage,
Current and power
Running.
Set current for the
last three steps
(descending order)