![Tettex TTR 2795 Operating Instructions Manual Download Page 84](http://html1.mh-extra.com/html/tettex/ttr-2795/ttr-2795_operating-instructions-manual_1092947084.webp)
80
Remote Control
Setup:Standard
This sets the Standard for the system.
Structure:
+S:Z:<Standard>:~:
Fields:
<Standard> (Integer) sets the standard. It is one of the following
0 - Do not change standard, this allows the standard to be queried
1 - Set to ANSI standard.
2 - Set to IEC standard.
3 - Set to AUS standard.
Returns:
+OK:<StandID>:~: - The standard was set successfully
+ERROR:0007:~: - Error writing the data
Comments:
The zero value allows the remote host to query standard followed. The function
returns the Standard ID code.
Setup:StepUnit
This sets the Step Unit for the system.
Structure:
+S:X:<StepUnit>:~:
Fields:
< StepUnit > (Integer) sets the tap-to-tap Step Unit of the transformer. It is one of
the
following
0 - Do not change Step Unit, this allows the Step Unit to be queried
1 - Set to Step Unit to VOLT
2 - Set to Step Unit to PERCENT
Returns:
+OK:<StepUnit>:~: - The Step Unit was set successfully
+ERROR:0007: ~: - Error writing the data
Comments:
The zero value allows the remote host to query Step Unit of the transformer. The
function returns the Step Unit
Setup:TapNumbering
This sets the Standard for the system.
Structure:
+S:Y:<TapNumbering>:~:
Fields:
< TapNumbering > (Integer) sets the Tap Numbering. It is one of the following
0 - Do not change Tap Numbering, this allows the Tap Numbering to be queried
1 - Set to Numeric format.
2 - Set to alphabetic format.
Returns:
+OK:< TapNumbering >:~: - The Tap Numbering was set successfully
+ERROR:0007: ~: - Error writing the data
Comments:
The zero value allows the remote host to query Tap Numbering format. The function
returns Tap Numbering.
Summary of Contents for TTR 2795
Page 1: ...Operating Instructions HAEFELY TEST AG TTR 2795 Transformer Turns Ratio Meter Version 1 4 ...
Page 10: ...6 Introduction Maximum Roll Diameter Outer 50mm Inner 10mm ...
Page 22: ...18 Connection and Setup Figure 11 Connecting to three phase BCT ...
Page 101: ...Application Software APSW 2795 97 ...
Page 111: ...Miscellaneous 107 14 7 Conformity ...