![Tettex TTR 2795 Operating Instructions Manual Download Page 63](http://html1.mh-extra.com/html/tettex/ttr-2795/ttr-2795_operating-instructions-manual_1092947063.webp)
Remote Control
59
“maintain” command to indicate connection is to be maintained if it is not transmitting commands. If the host is not
going to be transmitting data to the TTR for a period, it should send a “maintain” command every 2 seconds to keep
the link active. If the line is allowed to go idle for more than 2 seconds, the TTR will assume that the remote host has
disconnected and will reset the communications system and return itself to manual control.
Communications:Open
This attempts to place the TTR in remote control mode
Structure:
+C:O:~:
Fields:
None
Returns:
+OK:~: indicates a successful connection
+ERROR:0908:~: indicates the connection is refused because the TTR is being
controlled via the other port already (Error ES_NOCONN).
No Response - system shut off or the link is broken or system printing
Comments:
The TTR will generate no response if it is either shut down, or the remote is trying to
connect via the RS-232 port and the system is currently printing. The remote should retry the connection periodically
to see if connection can be gained.
Communications:Close
This closes down the communications link and ends remote control
Structure:
+C:C:~:
Fields:
None
Returns:
+OK:~: - indicates the connection has been closed.
Comments:
The TTR will generate no response if it is either shut down, or the remote is trying to
connect via the RS-232 port and the system is currently printing. The remote should retry the connection periodically
to see if connection can be gained.
Communications:Maintain
This maintains the communications link when the remote end is idle
Structure:
+C:M:~:
Fields:
None
Returns:
+OK:~: - indicates the maintain request has been received
Comments:
The Communications:Maintain command should be sent within two seconds of the
last command if the line is going to be idle for a period, to ensure that the communications link is maintained.
Identify
This gets the identity of the TTR being communicated with.
Structure:
+I:~:
Fields:
None
Returns:
+OK:TETTEX2795:<Serial No>:<Version>:~:
Summary of Contents for TTR 2795
Page 1: ...Operating Instructions HAEFELY TEST AG TTR 2795 Transformer Turns Ratio Meter Version 1 4 ...
Page 10: ...6 Introduction Maximum Roll Diameter Outer 50mm Inner 10mm ...
Page 22: ...18 Connection and Setup Figure 11 Connecting to three phase BCT ...
Page 101: ...Application Software APSW 2795 97 ...
Page 111: ...Miscellaneous 107 14 7 Conformity ...