4. Remove the three hex screws holding the
vacuum fan to the recovery tank. Note the
orientation of the exhaust port on the fan.
Remove the fan from the recovery tank.
Make sure to retain the three spacers.
5. Remove the exhaust muffler from the
existing fan and install on the new fan using
a plastic tie.
6. Install a gasket on the new vacuum fan
motor.
7. Install the new vacuum fan onto the
recovery tank. Reinstall the three hex
screws and spacers. Tighten to 5 – 6 Nm
(50 – 60 in lb).