SCRUBBING
3-43
5400 330735 (3–01)
TO REPLACE SOLUTION FLOW CONTROL
CABLE
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
1. Use a 5/64 inch allen wrench to loosen the
set screw holding the solution flow control
cable to the end of the valve. Pull the cable
off the valve.
2. Remove the four pan screws holding the
solution flow bracket assembly to the back
of the solution tank.
3. Use a small, flat screw driver to remove the
solution control knob from the top of the
cable.