ELECTRICAL
4-73
5400 330735 (3–01)
YES
NO
BOTH BRUSHES DO NOT OPERATE WITH BRUSH DECK DOWN
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO BATT. NEG.
(TWIST ROLL GRIPS
DURING TEST)
CHECK BRUSH DECK AND
FLOOR SURFACE FOR
CAUSE OF OVERLOAD
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
POSITIVE BATTERY
CABLE TO BATT. NEG.
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO NEGATIVE
STAND–OFF (TWIST ROLL
GRIPS DURING TEST)
RESET CIRCUIT
BREAKERS 1 AND 2
BRUSHES WORK?
NO
YES
REPAIR OR REPLACE
POSITIVE BATTERY
CABLE
GO TO
NEXT PAGE
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO 23 BLK
(TWIST ROLL GRIPS
DURING TEST)
NO
YES
NO
YES
NO
YES
REPAIR OR REPLACE
23 BLK
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
36/38 RED TO 27 BLK
(TWIST ROLL GRIPS
DURING TEST)
REPAIR OR REPLACE
27 BLK
GO TO
BRUSH 1 OR 2
DOES NOT OPERATE
YES
NO
IF ONE MOTOR WORKS:
GO TO – ONE BRUSH DOES
NOT OPERATE
START HERE
REPAIR OR REPLACE
NEGATIVE BATTERY
CABLE
Summary of Contents for 5400
Page 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Page 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Page 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Page 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Page 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Page 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Page 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Page 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Page 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Page 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Page 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Page 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Page 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...