ELECTRICAL
4-87
5400 330735 (3–01)
REPAIR OR REPLACE
21 BLK
SOLUTION SOLENOID DOES NOT OPERATE (BRUSHES WORK)
START
NO
YES
TURN ON MACHINE AND
LOWER BRUSHES TO THE
FLOOR. TURN SOLUTION
SWITCH ON.
YES
NO
REPLACE
SOLUTION SWITCH
NO
YES
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
16 BLU TO 91 BLK AT
FUSE HOLDER
(TWIST ROLL GRIPS
DURING TEST)
REPAIR OR REPLACE
16 BLU
YES
NO
REPLACE FUSE
GO TO
BOTH BRUSHES
DO NOT OPERATE
YES
NO
CHECK VOLTAGE AT
SOLUTION SOLENOID
24 GRY TO 21 BLK
(TWIST ROLL GRIPS
DURING TEST)
CHECK FOR WATER
SUPPLY PROBLEM
REPAIR OR REPLACE
SOLUTION SOLENOID
YES
NO
CHECK VOLTAGE AT
BRUSH CONTACTOR(CR2)
16 BLU TO 19 BLK
(TWIST ROLL GRIPS
DURING TEST)
CHECK VOLTAGE AT
SOLUTION SOLENOID
24 GRY TO 19 BLK
(TWIST ROLL GRIPS
DURING TEST)
CHECK VOLTAGE AT
SOLUTION SWITCH
16 BLU TO 19 BLK
(TWIST ROLL GRIPS
DURING TEST)
CHECK VOLTAGE AT
SOLUTION SWITCH
24 GRY TO 19 BLK
(TWIST ROLL GRIPS
DURING TEST)
REPAIR OR REPLACE
24 GRY
Summary of Contents for 5400
Page 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Page 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Page 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Page 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Page 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Page 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Page 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Page 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Page 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Page 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Page 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Page 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Page 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...