4. Orientate the solution valve and cable so the
set screw holding the cable end to the shaft
on the valve can be loosened. Use a 5/64
inch allen wrench to loosen the set screw.
5. Disconnect both solution hoses leading to
the valve.
6. Remove the two pan screws holding the
solution valve solenoid to the mount bracket.
7. Mark and disconnect both wires leading to
the existing valve. Remove the valve from
the machine. Reconnect the two wires to the
new solution valve. See the schematic in
this section. Note the direction of the diode
connected to the coil terminals. Make sure
the line side of the diode is connected to
wire #24 grey. Failure to do so will result in a
short circuit.
8. Install the new solution valve onto the mount
bracket. Reinstall the two pan screws and
tighten to 7 – 10 Nm (5 – 6 ft lb).
Turn the shaft on the solution control valve
clockwise with fingers until resistance is felt.
(this closes the valve opening)
Summary of Contents for 5400
Page 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Page 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Page 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Page 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Page 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Page 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Page 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Page 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Page 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Page 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Page 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Page 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Page 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...