ELECTRICAL
4-20
5400 330735 (3–01)
TO REPLACE 24 VOLT CONTACTOR
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
1. Open the instrument panel. See TO
ACCESS INSTRUMENT PANEL
instructions.
FOR SAFETY: Disconnect the battery
connections before working on the machine.
2. Locate the contactor at the bottom edge of
the instrument panel box.
3. Mark and disconnect the wires leading to the
contactor. Note the direction of the line
side of diode. Make sure the line side is
connected to wire 22YEL. Failure to do
so will result in a short circuit.
4. Remove the two hex nuts holding the
contactor to the panel. Remove the
contactor from the instrument panel.
5. Install the new contactor onto the instrument
panel. Install the two nuts and hand tighten
tight.
6. Reconnect the wires to the contactor. See
electrical schematic in this section. DO NOT
over tighten the wire connections on the
contactor posts or damage may occur.
7. Reinstall the instrument panel. See TO
ACCESS INSTRUMENT PANEL
instructions.
8. Operate the machine. Check the vacuum
fan for proper operation.
Summary of Contents for 5400
Page 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Page 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Page 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Page 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Page 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Page 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Page 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Page 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Page 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Page 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Page 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Page 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Page 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...