13. Position the new actuator and mount bracket
into the machine. Reinstall the contactor
mount plate and hour meter mount plate.
Install the four hex screws and tighten to
18 – 20 Nm (15 – 18 ft lb).
14. Align the hole in the bottom of the new
actuator lift tube with the mount hole in the
roller assembly. Reinstall the clevis pin and
cotter pin.
15. Remove the two pan screws holding the
hour meter mount plate to the solution tank.
Pull the hour meter mount plate up and out
of the way.
16. Connect the new lift actuator to the main
electrical harness.