ELECTRICAL
4-89
5400 330735 (3–01)
TURN ON ES SWITCH.
CHECK VOLTAGE AT ES
PUMP 70 PUR TO 71 BLK
REPAIR OR REPLACE
ES PUMP
CHECK VOLTAGE AT ES
PUMP 70 PUR TO 71 BLK
AT NEGATIVE STAND–OFF
IN ACCESSORY BOX
REPAIR OR REPLACE
71 BLK
CHECK VOLTAGE AT ES
PUMP 70 PUR TO
BATT. NEG.
CHECK VOLTAGE AT
TIMER RELAY 70 PUR TO
BATT. NEG.
REPAIR OR REPLACE
31 BLK
REPAIR OR REPLACE
70 PUR
CHECK VOLTAGE AT
TIMER RELAY 78 BLU TO
73 BLK
GO TO NEXT PAGE
CHECK VOLTAGE AT
TIMER RELAY 78 BLU TO
BATT. NEG.
START
NOTE: WATER LEVEL IN
RECOVERY TANK MUST
BE ABOVE FLOAT
SWITCH FOR TESTING
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
CHECK VOLTAGE AT ES
SWITCH 86 GRN TO BATT.
NEG.
CHECK VOLTAGE AT
TIMER RELAY 76 BLU TO
BATT. NEG.
CHECK VOLTAGE AT ES
SWITCH 76 BLU TO BATT.
NEG.
REPAIR OR REPLACE
73 BLK
REPAIR OR REPLACE
76 BLU
REPAIR OR REPLACE
78 BLU
Yes
No
Yes
No
Yes
No
REPLACE
ES SWITCH
GO TO NO POWER
TROUBLESHOOTING
Yes
No
ES
PUMP DOES NOT OPERATE
Summary of Contents for 5400
Page 1: ...330735 Rev 00 3 01 Service Manual 5400 ...
Page 4: ...GENERAL INFORMATION 1 2 5400 330735 3 01 ...
Page 16: ...CHASSIS 2 2 5400 330735 3 01 ...
Page 24: ...CHASSIS 2 10 5400 330735 3 01 ...
Page 26: ...SCRUBBING 3 2 5400 330735 3 01 ...
Page 70: ...SCRUBBING 3 46 5400 330735 3 01 ...
Page 72: ...ELECTRICAL 4 2 5400 330735 3 01 ...
Page 132: ...ELECTRICAL 4 62 5400 330735 3 01 ...
Page 137: ...ELECTRICAL 4 67 5400 330735 3 01 ...
Page 147: ...ELECTRICAL 4 77 5400 330735 3 01 ...
Page 151: ...ELECTRICAL 4 81 5400 330735 3 01 ...
Page 155: ...ELECTRICAL 4 85 5400 330735 3 01 ...
Page 161: ...ELECTRICAL 4 91 5400 330735 3 01 ...