ELECTRICAL
4-90
5400 330735 (3–01)
CHECK VOLTAGE AT
ES TIMER RELAY
72/74 ORG TO BATT. NEG.
REPLACE ES TIMER
RELAY
REPAIR OR REPLACE
74 ORG
CHECK VOLTAGE AT
FLOAT SWITCH
82 GRN TO BATT. NEG.
CHECK VOLTAGE AT
FLOAT SWITCH
74 ORG TO BATT. NEG.
REPLACE
FLOAT SWITCH
CHECK VOLTAGE AT
POSITIVE STAND–OFF IN
ACCESSORY BOX
82 GRN TO BATT. NEG.
GO TO NO POWER
TROUBLESHOOTING
REPAIR OR REPLACE
82 GRN
CONTINUED FROM
PREVIOUS PAGE
Yes
No
Yes
No
Yes
No
Yes
No
NOTE: WATER LEVEL IN
RECOVERY TANK MUST
BE ABOVE FLOAT
SWITCH FOR TESTING
ES