With both ports selected there are two traffic bars that show the amount of traffic on
each port and a traffic table with a Port column.
•
The active monitored streams are always displayed at the top of the list.
•
The columns are sortable.
•
The selected input is now highlighted in the ID column.
•
When the row has a yellow gradient, it indicates a signal that was present and is
now gone. Select the reset button at the right side of the banner (at the top) to
clear the signals that are no longer there.
Status Indicators
Indicates that the signal parameter has not been in an error condition.
Indicates that the signal parameter was in an error condition but the error has now
cleared.
Indicates that the signal parameter is currently in an error condition.
Indicates that the signal parameter is not being monitored for an error condition.
Elements of the IP Status Display
•
Port 1 and Port 2: Status of Port 1 and Port 2.
•
Total: Shows the total bit rate of the video in the IP stream.
•
IP stream bandwidth bar: The blue bar outline at the top of the display represents
the total bandwidth of the 10 GE pipe (10.3125 Gb/s). The blue bars inside the
outline show the relative bandwidth size of items in the IP stream compared to the
total available bandwidth of the stream. Numbers inside the blue bars correspond
to the ID numbers listed in the display.
•
Run Time: The instrument maintains a running IP Status Session. The Run Time
readout displays the amount of time that has elapsed during the current IP Status
Session. The time is displayed as "DD, HH:MM:SS", where DD is the number of days,
HH is the number of hours, MM is the number of minutes, and SS is the number of
seconds.
•
Clear icon: Select the Clear icon ( ) to reset the status session. After a reset, items
appear in the list in the order they are detected.
Summary of Contents for PRISM MPI
Page 1: ...PRISM MPI and MPX SDI IP Waveform Monitor User Manual April 2021 D00010020C...
Page 6: ...6 PRISM MPI MPX User Manual...
Page 10: ...10 PRISM MPI2 25 MPX2 25 User Manual...
Page 54: ...Getting Started Activity Center PRISM MPI MPX User Manual 54...
Page 76: ...Methods of Operation Remote Control through API Commands PRISM MPI MPX User Manual 76...
Page 138: ...Configure the Instrument Troubleshooting PRISM MPI MPX User Manual 138...