![Telestream PRISM MPI User Manual Download Page 113](http://html1.mh-extra.com/html/telestream/prism-mpi/prism-mpi_user-manual_1082248113.webp)
Configure the Instrument
Configure Reference Settings
113
PRISM MPI-MPX User Manual
5.
If you select the ST2059 profile and the communication mode, it is a mixture of
Multicast and Unicast, select
Mixed
SMPTE w/o negotiation
.
Note:
On the SMPTE profile mixed mode, the PTP Announce and Sync messages are
sent as Multicast. However, the Delay request and Delay Response messages are sent
as Unicast.
6.
Select the
Domain (0-127)
box to open the editing display.
7.
Use the editing controls to enter a new domain number. When using the editor:
– Select the Clear icon ( ) to remove the existing domain number.
– Select the
backspace
key to delete characters by backspacing over them.
8.
When you are done editing the domain number, select the
Enter
key.
9.
Repeat steps
4
to
6
for each PTP profile.