Using via Digital Data Communication
79
ALM Level
ALM level command corresponds to external output settings for alarm reset and status information.
Command Name
Summary
Command Type
ALM
-
-
:CLEar
Executes alarm reset
SET Only
:CONTain
-
-
:CC
Sets whether to include CC_STS in LEVEL1_ALM or not
Both
:CV
Sets whether to include CV_STS in LEVEL1_ALM or not
Both
ALM:CLEar
: Executes Alarm Reset
Function:
Executes alarm reset (Cancels generated Over Voltage/Over Current alarm)
Format:
ALM:CLEar
Type:
SET command only
No parameters
<Ex.>
ALM:CLE
ALM:CONTain:CC
:Sets whether to contain CC_STS in LEVEL1_ALM
Function:
Sets whether to contain CC_STS status in LEVEL1_ALM output condition.
Same as FUNCTION Settings Item 75
Format:
ALM:CONTain:CC <NRf>
Type:
SET command, QUERY command
Parameters:
0: Does not include in LEVEL1_ALM
1: Includes in LEVEL1_ALM
Response:
0, 1
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
· If analog option is not attached
· While operating as a parallel operation slave unit
<Ex.>
ALM:CONT:CC 1
ALM:CONT:CC?
1
Important note: Please perform alarm reset after removing the cause without fail.
!
CAUTION
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...