Controlling with External Analog & Contact Signals
142
Output Voltage Control with Isolated External Voltage
* This function can be set for isolation-option-featured type
"model name with I" only.
Output voltage is proportionate to the external DC voltage.
The external voltage is insulated from output of this machine.
Outputs from 0 to a rated output voltage for external voltages 0 to
10V.
The external voltage uses what can produce a 1mA current.
The output voltage is derived from the following formula.
Output Voltage [V]
=
10
]
[
Resistance
External
]
[
Voltage
Output
Maximum
kΩ
V
The output accuracy for the external voltage, is the set voltage ±
(0.2% of Rated Output Voltage).
Connecting
Connect the external voltage between No. 4 and 5 of the isolated control connector (accessory).
Setting Procedures
Set the parameter for FUNCTION item 40 to "1".
Set the parameter to 1 (External Voltage) according to the procedure on page
Twisted-Pair Wire
Output Voltage Control with Insulation External Voltage
External Voltage
0
~
10
V
Insulation Control Connector
4
5
The External Resistance A, B, and C and the External Voltage cannot be
used together to control the output.
!
CAUTION
MAX
10V
0
External Voltage
O
u
tp
u
t V
o
lta
g
e
CV_EXT/V
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...