Using via Digital Data Communication
113
HX-compatible Command Format
All commands and responses are ASCII character strings.
Characters "A" to "Z" are recognized as command strings and characters "+", "-", ".", and "0" to"9" are recognized as
parameters.
HX-compatible Command Group Sending
Multiple commands can be sent in a single string by separating commands with ",".
<Ex.>A1,MV10.00,MC2.00,OT1
However, a single string with multiple commands assigning addresses will error.
<Ex.>A1,OT1,A2,OT1 /* Error due to multiple address assignment commands */
Alarm Response Trigger Factors of HX-compatible Commands
In the event that any of the following error conditions are met, the HX-S-G4 power supply will promptly return an
alarm response "ALM128".
If an error is generated while inputting commands, recovery will not occur until delimiter is received.
To prevent this, make certain to send either "CR, LF, or CR+LF" when an alarm response is received.
When undefined command is received
When command parameters exceed the range
When a character or symbol other than numerals 0~9, +, -, and decimal point is sent in parameters
When sent with a single p
arameter containing more than 2 decimal points
When sent with spaces between the command and parameter
<Ex.>MV_35
Space
When a command is sent in lowercase
<Ex.>mv35
When a string received at one time (until delimiter is received) exceeds 128 cha
racters
Setting examples that are not errors
Throw away digits in parameters which exceed the maximum number of numerical places
<Ex> MV100.99
MV100.9
For HX-S-G4 Series power supplies, if either OVP, OCP or OHP error is generated, the alarm response will
change to "ALM160". During device errors, only "LV", "LC", "AR", "TP", and "TK" commands are valid. All other
commands will return alarm responses.
Delimiter of HX-compatible Command
Please add an end character (delimiter) to the end of commands being sent to the HX-S-G4 power supply.
Possible delimiters that can be used are listed below.
CR Carriage Return
LF Line Feed
CR+LF
Use any of the above as a delimiter.
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...