About this machine
10
Rear Panel
30
21
22
23
24 25
26 27
28
31
29
32
*1000V type is unimplemented
㉑
. ISOLATED CONTROL
Isolated Control Connector
This is the Status/Alarm Output Connector.
It is used for external analog control input of isolation type,
analog monitor output, and contact input when the isolation
analog option is mounted,
Use the included specialized connectors.
㉒
. SERIES CONTROL
Series Operation Control Connector
Connector for series connections.
When using in the slave mode, connect with the Master unit’s
minus output terminal using wires.
㉓
. EXTERNAL CONTROL
External Control Connector
Connectors for external analog control input and analog monitor
output.
Use the included specialized connectors.
㉔
. M/B CONTROL (IN)
Parallel Operation Control (Input) Connector
Control Signal Input Connector for parallel operations.
㉕
. M/B CONTROL (OUT)
Parallel Operation Control (Output) Connector
Control Signal Output Connector for parallel operations.
㉖
. TERMINATION
Termination Resistor ON/OFF Switch
When controlling one unit of this product via serial port, please
set the termination toggle switch to ON.
When using 2 or more power supplies, please set the first and
last units’ termination resistor ON/OFF switch to ON (set other
units' ones to OFF).
㉗
. SERIAL I/F 2
Serial Port/Multi-Channel Connectors
Connectors for when controlling multiple HX-S-G4 Series
units or for controlling RS-485 type, serial ports.
Connected with special cable. (T485-****: * is the code that
indicates length.)
㉘
. SERIAL I/F 1
Serial Port Connector
Connector for connecting computers etc. with serial cables
(RS-232C).
㉙
. LINE INPUT
Input Terminal Platform
This is the terminal platform that connects the power of this
product
㉚
. Ventilation Discharge Opening
Ventilation discharge opening for cooling the
product internally.
㉛
. M/B FG
FG terminal for parallel connection cable
This is the terminal for connecting the FG of parallel
connection cable.
㉜
.
PROTECTIVE EARTH TERMINAL (M5)
As for parallel connection cables, be sure to use the
special cable (HXPH-****:*specifies the length).
!
WARNING
Mandat ory
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...