Using via Digital Data Communication
93
[SOURce]:RESistance[:LEVel][:IMMediate][:AMPLitude]
: Sets internal resistance
Function:
Sets the internal resistance
Format:
[SOURce]:RESistance[:LEVel][:IMMediate][:AMPLitude] <NRf>
Type:
SET command, QUERY command
Parameters:
Range varies on the model and the number of parallel connected devices
Response:
Same as parameters
Model(Type)
Total Output
Capacity
30V Output Type
60V Output Type
500V Output Type
1000V Output Type
Internal
Resistance(m
Ω) Ranges
Internal
Resistance
Resolution
(mΩ)
Internal
Resistance(m
Ω) Ranges
Internal
Resistance
Resolution
(mΩ)
Internal
Resistance(Ω)
Ranges
Internal
Resistance
Resolution
(Ω)
Internal
Resistance(Ω)
Ranges
Internal
Resistance
Resolution
(Ω)
6kW
0 to 150
2
0 to 600
5
0 to 41.7
0.5
0 to 167
2
12kW
0 to 75.0
0.5
0 to 300
2
0 to 20.8
0.2
0 to 83
1
18kW
0 to 50.0
0.5
0 to 200
2
0 to 13.9
0.2
0 to 55.6
0.5
24kW
0 to 37.5
0.2
0 to 150
2
0 to 10.4
0.1
0 to 41.7
0.5
30kW
0 to 30.0
0.2
0 to 120
1
0 to 8.3
0.1
0 to 33.3
0.2
36kW
0 to 25.0
0.2
0 to 100
1
0 to 6.94
0.05
0 to 27.8
0.2
42kW
0 to 21.4
0.2
0 to 86
1
0 to 5.95
0.05
0 to 23.8
0.2
48kW
0 to 18.8
0.2
0 to 75.0
0.5
0 to 5.21
0.05
0 to 20.8
0.2
54kW
0 to 16.7
0.2
0 to 66.7
0.5
0 to 4.63
0.05
0 to 18.5
0.2
60kW
0 to 15.0
0.2
0 to 60.0
0.5
0 to 4.17
0.05
0 to 16.7
0.2
66kW
0 to 13.6
0.2
0 to 54.5
0.5
0 to 3.79
0.02
0 to 15.2
0.2
72kW
0 to 12.5
0.1
0 to 50.0
0.5
0 to 3.47
0.02
0 to 13.9
0.2
78kW
0 to 11.5
0.1
0 to 46.2
0.5
0 to 3.21
0.02
0 to 12.8
0.2
84kW
0 to 10.7
0.1
0 to 42.9
0.5
0 to 2.98
0.02
0 to 11.9
0.1
90kW
0 to 10.0
0.1
0 to 40.0
0.5
0 to 2.78
0.02
0 to 11.1
0.1
96kW
0 to 9.4
0.1
0 to 37.5
0.2
0 to 2.60
0.02
0 to 10.4
0.1
102kW
0 to 8.8
0.1
0 to 35.3
0.2
0 to 2.45
0.02
0 to 9.8
0.1
108kW
0 to 8.3
0.1
0 to 33.3
0.2
0 to 2.31
0.02
0 to 9.3
0.1
114kW
0 to 7.9
0.1
0 to 31.6
0.2
0 to 2.19
0.02
0 to 8.8
0.1
120kW
0 to 7.50
0.05
0 to 30.0
0.2
0 to 2.08
0.02
0 to 8.3
0.1
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
Cases other than full-featured type "model name with F"
·
While operating as a series operation slave unit
·
While operating as a parallel operation slave unit
<Ex.>
RES 150
RES?
150
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...