Basic Usage
44
Setting Operation during Alarm
Setting can be done about whether input shutoff is done or switching stop (forced output OFF) is done for this machine
at various types of alarm occurrence.
Setting Procedures
Press The Function “FUNC.” key.
The FUNC. lamp will light.
The Setting Item Number will display on the top Number Display
and the parameter will be displayed in the bottom Number
Display.
Select Item number 9 with the VOLTAGE dial.
Set Parameter to 0,1 or 2 with the CURRENT dial.
Parameter = 0 [Default value]:
When any alarm occurs, switching is stopped (forced output
OFF).
Parameter = 1:
At occurrence of TRIP input and serious failures (failures of
this machine), the input switch is turned off and input shutoff
is done.
Parameter = 2:
At occurrence of TRIP input, serious failures (failures of this
machine), over voltage (OVP), or over current (OCP), the
input switch is turned off and input shutoff is done.
Press the FUNC. key again to finalize settings.