Using via Digital Data Communication
101
SYSTem:CONTrol:CURRent:MODE
: Sets Mode for Current Setting Control Method
Function:
Sets mode for the method on setting the current
Same as FUNCTION Settings Item 71
Format:
SYSTem:CONTrol:CURRent:MODE <NRf>
Type:
SET command, QUERY command
Parameters: 0: Front Panel, Digital Communication
1: External Voltage
2: External Resistance Type-A
3: External Resistance Type-B
4: External Resistance Type-C
Response:
Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
- While operating as a series operation slave unit
- While operating as a parallel operation slave unit
<Ex.>
SYST:CONT:CURR:MODE 1
SYST:CONT:CURR:MODE?
1
SYSTem:CONTrol:CURRent:ISOLate
:
Sets Isolation for external analog control signal constant current (CC)
Function:
Sets isolation for external constant current (CC) analog signal
Same as FUNCTION Settings Item 41
Format:
SYSTem:CONTrol:CURRent:ISOLate <NRf>
Type:
SET command, QUERY command
Parameters: 0: Invalid
1: Valid
Response:
Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
- If isolated option is not attached
- While operating as a series operation slave unit
- While operating as a parallel operation slave unit
<Ex.>
SYST:CONT:CURR:ISOL 1
SYST:CONT:CURR:ISOL?
1
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...