Preparation and Connection
17
After wiring, be sure to set the attached output terminal cover.
Connecting Loads
Wiring material to the output terminal by attaching a crimp terminals in the figure below specified, please firmly tighten the
bolt / screw which is included.
30V/60V Type
Load
+
-
C1
C2
If you want to ground it is done at the
load end.
Do wiring material twisting,
Route as close as much as
possible.
M5 Screw
Output terminal cover
Load
+
-
C1
C2
If you want to ground it is done at the
load end.
Wiring
material
Do wiring material twisting,
Route as close as much as
possible.
M12 Bolt
M12 Crimping
terminal
Protective tube
Insulation lock
Output terminal
cover
500V/1000V Type
Wiring
material
M12 Crimping
terminal
Output Terminal Cover
(Photo is HX-S-0500-12G4)
Twisting wires can minimize the ripple and noise at the load terminal.
The noise level can be lowered to
be smaller than the standard value by connecting the C1
and C2 close to the load terminal.
Use C1 and C2 that are small and with high-frequency impedance, and connect the lead
wire cutting it as short as possible.
C1: Electrolytic Capacitor 100 to 1000 μF
C2: Film Capacitor 1 to 10 μF
MEMO
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...