Using in Series/Parallel Operation
124
Load Wire Connection
Connect wires from the Slave’s minus terminal to the Master’s plus terminal.
Connect wires from the Slave’s plus terminal to the Load’s plus terminal.
Connect wires from the Master’s minus terminal to the Load’s minus terminal.
Control Terminal Wiring
Connect wires from the Slave’s external control connector No. 21 terminal to the Master’s plus terminal.
Connect wires from the Series
control connector of the Slave to the Master’s minus terminal.
Connect wires from the Slave’s isolatedcontrol connector No. 15 terminal to the Master’s external control
connector No. 9 terminal.
Connect w
ires from the Slave’s isolated control connector No. 12 terminal to the Master’s external control
connector No. 10 terminal.
Connect w
ires from the Slave’s isolated control connector No. 16 terminal to the Master’s external control
connector No. 22 terminal.
Connect wi
res from the Master’s isolated control connector No. 15 terminal to the Slave’s external control
connector No. 9 terminal.
Connect wi
res from the Master’s isolated control connector No. 16 terminal to the Slave’s external control
connector No. 22 terminal.
* The signal lines of
,
,
,
, and
should be stranded wires.
Operation
1. Setting the Master
Press the Function "FUNC." key.
Select Item 10 with VOLTAGE dial.
Change the set value to 2 with CURRENT dial.
Press the FUNC. key again to finalize settings.
* For the function item 10 "Toggling Output ON/OFF with External Contacts", refer to page 129.
2. Setting the Slave
Press the Function "FUNC." key.
Select Item 73 with VOLTAGE dial.
Change the set value to 1 (Slave Mode) with CURR
ENT dial.
Press the FUNC. key again to finalize settings.
Turn the POWER switch OFF.
* The device will operate as a Slave unit when the POWER switch is turned ON again. At that time, the
"OUTPUT" lamp is lit.
3. Order of turning on “POWER” switch.
Turn on the power switch in orde of slave, then master.
Toggling Output ON/OFF with External Contacts in Series Operation
For the connecting refer to page133.
By setting this item, output ON of the Master is
prohibited when the input power of the Slave is
OFF.
When returning to Master, set FUNCTION Item 73
to 0, Item 51 to 0, and Item 60 to 1.
MEMO
MEMO
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...