Calibration
162
Calibration
Calibrating Output Settings
Preparation
The following measuring device is required for
calibration.
1. Digital Multimeter for Voltage/Current
Measurement- 1 set
No. of Display Digits : 5 1/2 or more
Display Accuracy : 0.005% or more
(Equipped with a measuring range from 1mV to
100V)
2. Shunt Resistor for Current Measurement- 1 set
30-200
30-400
60-100
60-200
200A/50mV
500A/50mV
200A/50mV
200A/50mV
500-12
500-24
1000-6
1000-12
15A/50mV
30A/50mV
10A/50mV
15A/50mV
*Please use the 0.1-class product.
Offset/Full Scale Calibration of Output Voltage Settings
1. Disconnect the load wires and the remote sensing
wires. Connect the digital multimeter to the output
terminal.
Turn the POWER switch ON and OUTPUT OFF in
advance.
Power Supply
+
-
V
+
-
Digital
Multimeter
Calibration Circuit
2. Set the constant voltage setting value to [ xV ]
and the constant current setting value to [ yA ] and
set the output to ON.
30-200
30-400
60-100
60-200
[xV]
0.01V
0.01V
0.01V
0.01V
[yA]
1.0A
1.0A
1.0A
1.0A
500-12
500-24
1000-6
1000-12
[xV]
0.1V
0.1V
1V
1V
[yA]
0.10A
0.10A
0.010A
0.10A
On how to set, see Operating as Constant Voltage
Power Supply under Basic Operations. (page27)
3. Press the FUNC. key.
4.
Turn the VOLTAGE dial to display the setting item
number 20 in the Number Display (voltage).
* At that time, turn off the Number Display (current).
5. Adjust so that the output voltage becomes [ xV ]
with the CURRENT dial.
30-200
30-400
60-100
60-200
[xV]
0.010V
0.010V
0.010V
0.010V
500-12
500-24
1000-6
1000-12
[xV]
0.10V
0.10V
1.0V
1.0V
6. Press the FUNC. key to settle the offset calibration
value of the output voltage settings.
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...