TE5251
User Manual
4-26
SINC:NCYCleN_cycles>(?)
Description
This command programs the number of “0-crossings” of the standard SINC pulse waveform. This command
has no affect on arbitrary waveforms.
Parameters
Name
Range
Type
Default
Description
<N_cycle>
4 to 100
Numeric
(Integer
only)
10
Programs the number of zero-crossings parameter
Response
The 5251 will return the present number of zero-crossing value.
GAUSsian:EXPonent<exp>(?)
Description
This command programs the exponent for the standard gaussian pulse waveform. This command has no
affect on arbitrary waveforms.
Parameters
Name
Range
Type
Default
Description
<exp>
4 to 100
Numeric
20
Programs the exponent parameter
Response
The 5251 will return the present exponent value.
EXPonential:EXPonent<exp>(?)
Description
This command programs the exponent for the standard exponential waveform. This command has no affect
on arbitrary waveforms.
Parameters
Name
Range
Type
Default
Description
<exp>
-100 to
100
Numeric
1
Programs the exponent parameter
Response
The 5251 will return the present exponent value.
Summary of Contents for 5251
Page 17: ...List of Figures continued xiv...
Page 35: ...TE5251 User Manual 1 18 This page was intentionally left blank...
Page 37: ...TE5251 User Manual 2 2...
Page 134: ...TE5251 User Manual 3 82 Figure 3 62 Log File Example...
Page 222: ...TE5251 User Manual 4 88 This page was left intentionally blank...
Page 258: ...TE5251 User Manual 5 36 This page was intentionally left blank...
Page 288: ...TE5251 User Manual 6 30 This page was intentionally left blank...
Page 289: ...1 Appendices Appendix Title Page A Specifications A 1...
Page 290: ...TE5251 User Manual 2...