User Manual of SY5000 series AC Drive Parameter instrction
~79~
and still is under operation status, otherwise disconnects.
Under-voltage locking signal——if [E-054] setting is 4, output of relay Y1 is
under-voltage locking signal. Relay Y1 closes when under-voltage failure (display
‘P.oFF’) happens otherwise disconnects.
(Note: relay closing means Y10, Y11 connecting, Y10, Y12 disconnecting; relay
disconnecting means Y10, Y11 disconnecting, Y10, Y12 closing.)
Parameter code of PID regulation (group P)
P-000 PID regulation selection
When this parameter is 0 , PID regulation is inenabled
;
when this parameter is 1
,
PID regulation is enabled
。
PID regulation diagram is as shown at below.
P-001 given quantity channel selection
This parameter is used to select setting method of given value:
[P-001] = 0
:
given value is setting voltage value of [P-002];
[P-001] = 1
:
given value is setting current value of [P-003];
[P-001] = 2
:
given value is analog voltage input V2-GND
;
[P-001] = 3
:
given value is analog current inputI2-GND
。
P-002 digital voltage setting value
When [P-001] = 0, given value controlled by PID is determined by this
parameter value.
P-003 digital current setting value
When [P-001] = 1, given value controlled by PID is determined by this
parameter value.
P-004 feedback value channel selection
This parameter is used to select setting method of feedback value:
[P-004] = 0
:
Feedback value is analog voltage input signal V2-GND;
[P-004] = 1
:
Feedback value is analog current input signal I2-GND.
*********************************************************
* Note
:
[P-004] and [P-001] selected channels can not be repeated.
*********************************************************
P-005 feedback value bias
P-006 feedback value gain
P-007 positive/negative characteristics of feedback value
[P-005] ~ [P-007] are used to feedback calculation value when PID regulates.
When actual feedback value can’t meet PID regulation requirement, you can adjust