User Manual of SY5000 series AC Drive Parameter instrction
~70~
E-030 positive characteristics / negative characteristic
E-031 analog input bias
E-032 analog input gain
E-030 is used to select positive/ negative characteristics when set frequency
method by external analog input
(
analog voltage input0~5V/10V, external analog
current input 4~20mA, panel potentiometer
)
.
0——positive characteristic
;
1—— negative characteristic
When set frequency by external analog signal input
(
0~5V/10V
,
4~20mA
)
or
panel potentiometer, you can set output frequency by adjusting values of E-031 and
E-032.
Initial settings of inverter: input: 0~5V, corresponding output frequency: 0 ~
highest frequency
(
50.00 Hz
)
,
Input-output characteristic curve (see below left figure) can be expressed
at
below:
,
X means input voltage
,
Y means output frequency
,
at this time, bias
E-031 = 0.0
,
gain E-032 = 1.00.