1. If CDU A is mounted in the position just above the upper-most shelf in the
rear of the cabinet, support the CDU in position against the rear vertical
cabinet rails while removing its mounting screws, as shown in Figure 6–5.
If the position just above the upper-most shelf is open, install four U-nuts on
the vertical cabinet rails, as shown in Figure 6–6.
2. Position the air separation panel against the front panel of CDU A or the four
U-nuts, as shown in either Figure 6–5 or 6–6, respectively.
3. Fasten the air separation panel (along with CDU A, if appropriate) to the
rear vertical cabinet rails with four screws, as shown.
Figure 6–5 Rear Air Separation Panel Installation (Shelf installed directly below CDU A)
REAR VERTICAL
CABINET RAIL
CDU A
CDU MOUNTING
SCREW
(4 PLACES)
CXO-3929A-MC
AIR
SEPARATION
PANEL
UPPER-MOST
SHELF
6–8 Installing StorageWorks Shelves