4.2 Filler and Air Separation Panels
Note
To maintain FCC compliance and proper airflow, filler panels and air
separation panels must be installed as specified for your particular
cabinet configuration and in accordance with the following guidelines.
Filler panels can be installed in empty shelf positions to control air flow and
electromagnetic emissions and for the purpose of cosmetics. Filler panels are
normally supplied and installed based on the specific configuration of the SH043
storage-only cabinet ordered. At least two filler panels are shipped with each
cabinet. Install filler panels using the following guidelines:
• If a particular filler panel configuration is specified for your cabinet, install
the panels exactly as specified.
• If a particular filler panel configuration is not specified for your cabinet, use
filler panels in all open slots
below
the highest shelf installed. Repeat for
each side of the cabinet.
• To ensure proper cooling air flow, never install filler panels
above
the highest
shelf installed in the cabinet.
See Chapter 6 for details on the installation of filler panels.