Page 44
• Place alligator clips on the B+ terminal and the field terminal of the
alternator.
• Step on the machine for 15 - 20 seconds.
• If resistance is achieved during this time, your alternator has
correct current flow.
• If no resistance builds up during this time, you either have a bad
alternator or bad alternator brushes.
12.
Unplug the diode from the FLD terminal of the alternator.
13.
Use a multimeter set to ohms to test the diode. A good diode will
show a high resistance reading in one direction and a low resistance
reading when the multimeter leads are reversed.
14.
Unplug the load resistor from the power control board. Set your
multimeter to ohms. Insert the multimeter leads into the load resistor
plug.
15.
A load resistor in proper working condition should read approximately
0.5 ohms. If there is no resistance when measured by a multimeter,
replace the load resistor.
16.
Check the main cable assemblies for continuity and cross check each
wire in the cables to test for shorts in the cable.
17.
Contact our Customer Service Department at (800) 331-3578 for
assistance. International customers should contact their local
distributors.
TROUBLESHOOTING
Summary of Contents for FREERUNNER 5600
Page 1: ...FREERUNNER 5600 OWNER S MANUAL...
Page 98: ...Page 89 Figure 22 Leg Assembly APPENDIX...
Page 99: ...Page 90 Figure 23 Heel Link Assembly APPENDIX...
Page 101: ...Page 92 APPENDIX Figure 25 Pedal Assembly...
Page 103: ...Page 94 Figure 27 Heel Link Pivot Adjustment APPENDIX...
Page 104: ...Page 95 Figure 28 Handle Assembly APPENDIX...
Page 106: ...Page 97 Figure 30 Power Control Board A APPENDIX...
Page 107: ...Page 98 APPENDIX Figure 31 LED Panel...
Page 108: ...Page 99 APPENDIX Figure 32 Power Control Board B...
Page 109: ...Page 100 APPENDIX Figure 33 Alternator Cable...