Basic timers (TIM6&TIM7)
RM0008
458/1096
Doc ID 13902 Rev 12
Figure 178. Control circuit in normal mode, internal clock divided by 1
17.3.4 Debug
mode
When the microcontroller enters the debug mode (Cortex-M3 core - halted), the TIMx
counter either continues to work normally or stops, depending on the DBG_TIMx_STOP
configuration bit in the DBG module. For more details, refer to
support for timers, watchdog, bxCAN and I2C
.
17.4 TIM6&TIM7
registers
Refer to
for a list of abbreviations used in register descriptions.
The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).
17.4.1 TIM6&TIM7
control
register 1 (TIMx_CR1)
Address offset: 0x00
Reset value: 0x0000
CK_INT
00
Counter clock = CK_CNT = CK_PSC
Counter register
01 02 03 04 05 06 07
32 33 34 35 36
31
CEN=CNT_EN
UG
CNT_INIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reserved
ARPE
Reserved
OPM
URS
UDIS
CEN
rw
rw
rw
rw
rw
Bits 15:8 Reserved, always read as 0
Bit 7
ARPE
: Auto-reload preload enable
0: TIMx_ARR register is not buffered.
1: TIMx_ARR register is buffered.
Bits 6:4 Reserved, always read as 0
Bit 3
OPM
: One-pulse mode
0: Counter is not stopped at update event
1: Counter stops counting at the next update event (clearing the CEN bit).