SSI700 User Manual Description of Function Codes
www.ssinverter.info
These five parameters are used to select the functions of the five digital output terminals.
T/A-T/B-T/C are respectively the relays on the control board .
The functions of the output terminals are described in the following table.
Table 6-5 Functions of output terminals
Value
Function
Description
0
No output
The terminal has no function.
1
AC drive running
When the AC drive is running and has output frequency
(can be zero), the terminal becomes ON.
2
Fault output (stop)
When the AC drive stops due to a fault, the terminal
becomes ON.
3
Frequency-level detection
BRAKE control 1 output
Refer to the descriptions of P8-19 and P8-20.
4
Frequency reached
Refer to the descriptions of P8-21.
5
Zero-speed running (no output
at stop)
If the AC drive runs with the output frequency of 0, the
terminal becomes ON. If the AC drive is in the stop state,
the terminal becomes OFF.
6
Motor overload pre-warning
The AC drive judges whether the motor load exceeds the
overload pre-warning threshold before performing the
protection action. If the pre-warning threshold is exceeded,
the terminal becomes ON. For motor overload
parameters,see the descriptions of P9-00 to P9-02.
7
AC drive overload prewarning
The terminal becomes ON 10s before the AC drive overload
protection action is performed.
8
Set count value reached
The terminal becomes ON when the count value reaches
the value set in 11-08.
9
Designated count value
reached
The terminal becomes ON when the count value reaches
the value set in 11-09.
10
Length reached
The terminal becomes ON when the detected actual length
exceeds the value set in 11-05.
11
PLC cycle complete
When simple PLC completes one cycle, the terminal
outputs a pulse signal with width of 250 ms.
12
Accumulative running time
reached
If the accumulative running time of the AC drive exceeds
the time set in P8-17, the terminal becomes ON.
13
Frequency limited
If the set frequency exceeds the frequency upper limit or
lower limit and the output frequency of the AC drive reaches
the upper limit or lower limit, the terminal becomes ON.
14
Torque limited
In speed control mode, if the output torque reaches the
torque limit, the AC drive enters the stall protection state
and meanwhile the terminal becomes ON.
15
Ready for RUN
If the AC drive main circuit and control circuit become
stable, and the AC drive detects no fault and is ready for
RUN, the terminal becomes ON.
16
AI1 larger than AI2
When the input of AI1 is larger than the input of AI2, the
terminal becomes ON.
17
Frequency upper limit reached
If the running frequency reaches the upper limit, the
terminal becomes ON.
18
Frequency lower limit reached
(no output at stop)
If the running frequency reaches the lower limit, the terminal
becomes ON. In the stop state, the terminal becomes OFF.
19
Undervoltage state output
If the AC drive is in undervoltage state, the terminal
becomes ON.
20
Communication
setting Refer to the communication protocol.
21,22
Reserved Reserved.
23
Zero-speed running 2 (having
output at stop)
If the output frequency of the AC drive is 0, the terminal
becomes ON. In the state of stop, the signal is still ON.
24
Accumulative poweron time
reached
If the AC drive accumulative power-on time (P7-13)
exceeds the value set in P8-16, the terminal becomes ON.
25
Frequency level detection
BRAKE control 2 output
Refer to the descriptions of P8-28 and P8-29.
Summary of Contents for SSI700
Page 1: ......
Page 3: ...Safety Information and Precautions...
Page 7: ...Product Information...
Page 12: ...Mechanical and Electrical Installation...
Page 19: ...Operation Display and Application Examples...
Page 42: ...Function Code Table...
Page 64: ...Description of Function Codes...
Page 131: ...EMC...
Page 137: ...Selection and Dimensions...
Page 141: ...Maintenance and Troubleshooting...